B maXX 5000
Click vào đây để liên hệ với chúng tôi nếu có thông tin mà quý khách cần!!!http://nhathuycorp.net
Side-by-side, flexible, and energy-efficient servo converter
Safety:
- Plug-in module, optionally with or without safety functions
- Three different safety modules with scalable functionality
- All modules with integrated parameter memory for safe and unsafe data
- Safety functions according to IEC 61800-5-2
- Power output for motor brake
- Choice of safety functions via local safe I/O or EtherCAT FSoE
DC link capacity unit for the b Maxx 5000 series
Using the dc link capacity unit at dynamic applications the braking energy can be temporarily stored and be used for the following acceleration.
The temporary storage of the braking energy – Low energy demand
Peak load leveling – Reduction of the peak loads with the EVU agreed by contract
Smaller dimensioning of the switching cabinet and the rectifier unit – Low space requirements, as well as cost saving, are possible
Temporarily stored energy permits the controlled shutting down of the system if disturbances or power failures occur – Reduction of costs by going without an independent power supply (USV)
Technical data b Maxx 5000 Mains rectifier units
Technical data b maXX 5100 Mains regenerative feedback units
Baugröße | Zwischenkreisleistung [kW] | Zwischenkreisspitzenleistung [kW] | Überlastfaktor | Abmessungen BxHxT [mm] | ||
---|---|---|---|---|---|---|
BM 5143 | 4 | 36 | 52 | 1,4 | 100 x 395 x 280 / 210 2) | |
BM 5174 | 7 | 64 | 96 | 1,5 | 175 x 395 x 280 / 210 2) | |
BM 5192 | 9 | 150 | 300 | 2 | 425 x 395 x 280 / 210 3) | |
BM 5193 | 9 | 200 | 300 | 1,5 | 425 x 395 x 210 3) |